Energy Redefined.
nextcellenergy.com
24V 100Ah LiFePO4 Datasheet
Compact wall-mounted storage for homes, small offices and entry-level solar systems.
Technical Specifications
| Model | 256100 (8S1P LiFePO4) |
| Nominal Voltage | 25.6 V |
| Capacity | 100 Ah |
| Energy | 2,560 Wh (2.56 kWh) |
| Charge Cut-off | 28.8 V |
| Discharge Cut-off | 18.4 V |
| Standard Charge Current | 50 A |
| Max Charge Current | 100 A |
| Max Continuous Discharge | 120 A |
| Cycle Life | ≥ 4,000 cycles @ 80% DoD |
| Dimensions | 465 × 320 × 200 mm |
| Weight | 26.22 kg |
| Terminals | M8 |
| Operating Temperature | Charge 0°C to 45°C · Discharge -20°C to 60°C |
| Cooling | Natural convection (silent) |
| Chemistry | LiFePO4 (Lithium Iron Phosphate) |
| BMS | Smart BMS with LCD display |
| Design | Wall-mount |
Key Features
- Smart BMS with live LCD readout
- Slim wall-mount enclosure
- Fast, efficient charging
- Inverter compatible
- Maintenance-free
Inverter Compatibility
Sunsynk · Deye · Victron · Luxpower · Growatt · Voltronic
Wiring Instructions
- Switch off the inverter, the battery breaker and all PV / AC inputs before starting.
- Mount the battery on a solid, dry wall away from direct sun and heat sources.
- Connect the battery positive (+) to the inverter battery positive and negative (−) to negative, using correctly rated cable and a DC breaker/fuse. Double-check polarity.
- For parallel systems (48V), use equal-length cables and connect to a common busbar.
- Connect the earth point to the installation earth (resistance < 0.1 Ω).
- Set the inverter battery type to LiFePO4 and the charge voltage within the battery's charge cut-off.
- Switch on the battery breaker, then the inverter. Confirm voltage and state of charge on the LCD.
[ PV / Grid ] ──► [ INVERTER ] ──► [ Home loads ]
│ ▲
(+) red │ │ (−) black
▼ │
[ DC BREAKER ]
│
[ NEXTCELL BATTERY ] ── earth (< 0.1 Ω)Installation must be done by a qualified professional with a valid Certificate of Compliance (COC).
Warranty
5-Year Limited Manufacturer Warranty (covering ≥ 4,000 cycles). Requires professional installation and COC compliance.